2 pr eset ting aut o matically – HEIDENHAIN TNC 320 (340 55x-03) Touch Probe Cycles User Manual
Page 100

100
3.2 Pr
eset
ting aut
o
matically
8
Measuring axis (1...3: 1=reference axis)
Q272:
Axis in which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis
3: Touch probe axis = measuring axis
8
Traverse direction
Q267: Direction in which the
probe is to approach the workpiece:
-1: Negative traverse direction
+1: Positive traverse direction
8
Datum number in table
Q305: Enter the number in the
datum or preset table in which the TNC is to save the
coordinate. If you enter Q305=0, the TNC
automatically sets the display so that the new datum
is on the probed surface.
8
New datum
Q333 (absolute): Coordinate at which the
TNC should set the datum. Basic setting = 0
8
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. See “Saving the calculated datum,”
page 64
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).
Example: NC blocks
5 TCH PROBE 419 DATUM IN ONE AXIS
Q263=+25
;1ST POINT 1ST AXIS
Q264=+25
;1ST POINT 2ND AXIS
Q261=+25
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+50
;CLEARANCE HEIGHT
Q272=+1
;MEASURING AXIS
Q267=+1
;TRAVERSE DIRECTION
Q305=0
;NO. IN TABLE
Q333=+0
;DATUM
Q303=+1
;MEAS. VALUE TRANSFER
Axis assignment
Active touch probe
axis: Q272 = 3
Corresponding
reference axis:
Q272 = 1
Corresponding
minor axis:
Q272 = 2
Z
X
Y
Y
Z
X
X
Y
Z