beautypg.com

3 a u to matic w o rk piece measur ement – HEIDENHAIN TNC 320 (340 55x-03) Touch Probe Cycles User Manual

Page 138

background image

138

3.3 A

u

to

matic W

o

rk

piece Measur

ement

8

1st measuring point in 1st axis

Q263 (absolute):

coordinate of the first touch point in the reference
axis of the working plane.

8

1st measuring point in 2nd axis

Q264 (absolute):

coordinate of the first touch point in the minor axis of
the working plane.

8

1st measuring point in 3rd axis

Q294 (absolute):

coordinate of the first touch point in the touch probe
axis.

8

2nd measuring point in 1st axis

Q265 (absolute):

coordinate of the second touch point in the reference
axis of the working plane

8

2nd measuring point in 2nd axis

Q266 (absolute):

coordinate of the second touch point in the minor axis
of the working plane

8

2nd measuring point in 3rd axis

Q295 (absolute):

coordinate of the second touch point in the touch
probe axis.

8

3rd measuring point in 1st axis

Q296 (absolute):

coordinate of the third touch point in the reference
axis of the working plane.

8

3rd measuring point in 2nd axis

Q297 (absolute):

coordinate of the third touch point in the minor axis of
the working plane.

8

3rd measuring point in 3rd axis

Q298 (absolute):

coordinate of the third touch point in the touch probe
axis.

8

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to column SET_UP.

8

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

8

Measuring log

Q281: Definition of whether the TNC is

to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR431.TXT
by default in the directory TNC:\
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.

Example: NC blocks

5 TCH PROBE 431 MEASURE PLANE

Q263=+20

;1ST POINT 1ST AXIS

Q264=+20

;1ST POINT 2ND AXIS

Q294=-10

;1ST POINT 3RD AXIS

Q265=+50

;2ND POINT 1ST AXIS

Q266=+80

;2ND POINT 2ND AXIS

Q295=+0

;2ND POINT 3RD AXIS

Q296=+90

;3RD POINT 1ST AXIS

Q297=+35

;3RD POINT 2ND AXIS

Q298=+12

;3RD POINT 3RD AXIS

Q320=0

;SET-UP CLEARANCE

Q260=+5

;CLEARANCE HEIGHT

Q281=1

;MEASURING LOG

X

Y

Q297

Q263

Q264

Q266

Q296

Q265

X

Z

Q295
Q298

Q294

Q260

MP6140

+

Q320

This manual is related to the following products: