Making router control system connections – Grass Valley NV8500 Series v.3.5 User Manual

Page 122

background image

106

Expanded NV8576-Plus

Connecting the NV8576-Plus Frames

Making Router Control System Connections

An NV8576-Plus router with EM0666 control cards (i.e., standard router) the cross-connection
uses RJ-45 cables with terminators.

An NV8576-Plus router with EM0833 control cards (i.e., hybrid router) the cross-connection uses
BNC cables without terminators.

For Routers with EM0666 Control Cards

1 Face the rear of the router frames. Locate the RTR EXP connectors (RJ-45).

Fig. 6-9: RJ-45 Control Connections

Connect RTR EXP on one frame to RTR EXP on the other frame. Place terminators in the unused
RJ-45 ports.

For Routers with EM0833 Control Cards

1 Face the rear of the router frames.

Fig. 6-10: BNC Control Connections

2 Using a 75

W BNC cable, connect RTR EXP IN on frame 1 to RTR EXP OUT on frame 2.

3 Using a 75

W BNC cable, connect RTR EXP OUT on frame 1 to RTR EXP IN on frame 2.

Because the cables are paired, you can use two cables for redundancy.

Expansion Connectors (RJ-45)

Note

Miranda provides the terminators (WC0084). They are small; be careful not to overlook them.

Expansion Connectors (BNC)

This manual is related to the following products: