Rebooting a card or the switch – H3C Technologies H3C S7500E Series Switches User Manual
Page 84
73
Task Command
Remarks
Save the running configuration to a file
other than the startup file for the next
reboot.
save file-url [ all |
[ chassis
chassis-number ] slot
slot-number ]
Available in any view.
•
The extension of the configuration file
must be .cfg.
•
You specify chassis chassis-number only
when the switch is in IRF mode.
•
The all keyword saves the configuration
to all SRPUs.
•
In standalone mode, if neither all nor slot
slot-number are specified, the command
saves the configuration to the active
SRPU.
•
In IRF mode, if neither all nor chassis
chassis-number slot slot-number are
specified, the command saves the
configuration to the active SRPU on the
master switch.
Save the running configuration to the
root directory of the storage medium
and specify the file as the startup
configuration file for the next reboot.
save [ safely ]
[ force ]
Available in any view.
NOTE:
The startup configuration file for the next reboot might be lost if a reboot or power failure occurs during the
saving process, and the switch will reboot with the default configuration. After the switch reboots, you must
re-specify the startup configuration file for the next reboot.
For more information about the save commands, see the fundamentals configuration guide for the H3C
S7500E switches.
Rebooting a card or the switch
You must reboot the switch after you upgrade or maintain its boot file or configuration file. You must also
reboot an SRPU or LPU after you change its operating mode. The following methods are available for you
to reboot the switch or a card:
•
Reboot the switch or a card at once.
•
Schedule an automatic reboot of the switch at a specific data and time, or after a certain amount
of time.
•
Power off and then power on the switch. Use this approach with caution. Powering off a running
switch can cause data loss and hardware damages.
To reboot the switch or a card at once:
Task Command
Remarks
Reboot the switch or a card other
than the standby SRPU at once (in
standalone mode).
reboot [ slot
slot-number ]
Available in user view.
If no slot is specified, the command reboots the
entire switch.