Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual
Page 69
60
[SwitchA-Vfc2] bind interface ten-gigabitethernet 1/0/2
[SwitchA-Vfc2] port trunk vsan 20
[SwitchA-Vfc2] quit
# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.
[SwitchA] interface ten-gigabitethernet 1/0/2
[SwitchA-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchA-Ten-GigabitEthernet1/0/2] quit
# Create interface VFC 4, and configure it to operate in E mode.
[SwitchA] interface vfc 4
[SwitchA-Vfc4] fc mode e
# Bind interface VFC 4 to interface Ten-GigabitEthernet 1/0/4, and assign it to VSANs 10 and 20
as a trunk port.
[SwitchA-Vfc4] bind interface ten-gigabitethernet 1/0/4
[SwitchA-Vfc4] port trunk vsan 10 20
[SwitchA-Vfc4] quit
# Assign interface Ten-GigabitEthernet 1/0/4 to VLANs 10 and 20 as a trunk port.
[SwitchA] interface ten-gigabitethernet 1/0/4
[SwitchA-Ten-GigabitEthernet1/0/4] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/4] port trunk permit vlan 10 20
[SwitchA-Ten-GigabitEthernet1/0/4] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 10.
[SwitchA] vlan 10
[SwitchA-vlan10] fcoe enable vsan 10
[SwitchA-vlan10] quit
# Enable FCoE for VLAN 20 and map VLAN 20 to VSAN 20.
[SwitchA] vlan 20
[SwitchA-vlan20] fcoe enable vsan 20
[SwitchA-vlan20] quit
2.
Configure Switch B in the same way Switch A is configured. (Details not shown.)
Verifying the configuration
1.
Verify the configuration on Switch A by displaying member interfaces of all VSANs.
[SwitchA] display vsan port-member
VSAN 1:
Access Ports:
Trunk Ports:
VSAN 10:
Access Ports:
Trunk Ports:
Vfc1
Vfc4
VSAN 20:
Access Ports: