Verifying the configuration, Configuring the allowed domain id list – H3C Technologies H3C S12500-X Series Switches User Manual
Page 53

44
[SwitchB-Ten-GigabitEthernet1/0/1] quit
# Create interface VFC 1, and configure it to operate in F mode.
[SwitchB] interface vfc 1
[SwitchB-Vfc1] fc mode f
# Bind interface VFC 1 to interface Ten-GigabitEthernet 1/0/1, and assign it to VSAN 1 as a trunk
port.
[SwitchB-Vfc1] bind interface ten-gigabitethernet 1/0/1
[SwitchB-Vfc1] port trunk vsan 1
[SwitchB-Vfc1] quit
# Assign interface Ten-GigabitEthernet 1/0/1 to VLAN 10 as a trunk port.
[SwitchB] interface ten-gigabitethernet 1/0/1
[SwitchB-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/0/1] quit
# Create interface VFC 2, and configure it to operate in E mode.
[SwitchB] interface vfc 2
[SwitchB-Vfc2] fc mode e
# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/0/2, and assign it to VSAN 1 as a trunk
port.
[SwitchB-Vfc2] bind interface ten-gigabitethernet 1/0/2
[SwitchB-Vfc2] port trunk vsan 1
[SwitchB-Vfc2] quit
# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.
[SwitchB] interface ten-gigabitethernet 1/0/2
[SwitchB-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/0/2] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit
Verifying the configuration
1.
Verify the configuration on Switch A.
[SwitchA] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 11:11:11:11:11:11:11:11
Priority: 128
Domain ID: 1
Configuration information:
Domain configure: Disabled
Domain auto-reconfigure: Disabled