H3C Technologies H3C S12500-X Series Switches User Manual
Page 35

26
[SwitchA-vlan10] quit
# Assign interface Ten-GigabitEthernet 1/0/1 to VLAN 10, and configure the interface to operate
in ENode mode.
[SwitchA] interface ten-gigabitethernet 1/0/1
[SwitchA-Ten-GigabitEthernet1/0/1] port link-mode bridge
[SwitchA-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/1] port trunk permit vlan 10
[SwitchA-Ten-GigabitEthernet1/0/1] fip-snooping port-mode enode
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10, and configure the interface to operate
in FCF mode.
[SwitchA] interface ten-gigabitethernet 1/0/2
[SwitchA-Ten-GigabitEthernet1/0/2] port link-mode bridge
[SwitchA-Ten-GigabitEthernet1/0/2] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10
[SwitchA-Ten-GigabitEthernet1/0/2] fip-snooping port-mode fcf
[SwitchA-Ten-GigabitEthernet1/0/2] quit
# Configure the FC-MAP value as 0x0EFC01 for VLAN 10.
[SwitchA] vlan 10
[SwitchA-vlan10] fip-snooping fc-map 0efc01
[SwitchA-vlan10] quit
2.
Configure Switch B:
# Configure Switch B to operate in advanced mode, save the configuration, and reboot Switch B.
(Skip this step if the switch is operating in advanced mode.)
[SwitchB] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
The system working mode is changed, please save the configuration and reboot the
system to make it effective.
# Configure Switch B to operate in FCF mode.
[SwitchB] fcoe-mode fcf
# Configure the FC-MAP value as 0x0EFC01.
[SwitchB] fcoe fcmap 0efc01
# Create VSAN 10.
[SwitchB] vsan 10
[SwitchB-vsan10] quit
# Create interface VFC 2, and configure it to operate in F mode.
[SwitchB] interface vfc 2
[SwitchB-Vfc2] fc mode f
# Bind interface VFC 2 to interface Ten-GigabitEthernet 1/0/2, and assign it to VSAN 10 as a
trunk port.
[SwitchB-Vfc2] bind interface ten-gigabitethernet 1/0/2
[SwitchB-Vfc2] port trunk vsan 10
[SwitchB-Vfc2] quit
# Assign Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.