beautypg.com

Verifying the configuration, Overview of rscn aggregation, Configuration procedure – H3C Technologies H3C S12500-X Series Switches User Manual

Page 62

background image

53

# Assign interface Ten-GigabitEthernet 1/0/2 to VLAN 10 as a trunk port.

[SwitchD] interface ten-gigabitethernet 1/0/2

[SwitchD-Ten-GigabitEthernet1/0/2] port link-type trunk

[SwitchD-Ten-GigabitEthernet1/0/2] port trunk permit vlan 10

[SwitchD-Ten-GigabitEthernet1/0/2] quit

# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.

[SwitchD] vlan 10

[SwitchD-vlan10] fcoe enable vsan 1

[SwitchD-vlan10] quit

Verifying the configuration

1.

Verify the configuration on Switch A:
# Display the domain information of VSAN 1.

[SwitchA] display fc domain vsan 1

Domain Information of VSAN 1:

Running time information:

State: Stable

Switch WWN: 48:33:43:2d:46:43:1A:1A

Fabric name: 48:33:43:2d:46:43:1B:1B

Priority: 128

Domain ID: 11

Configuration information:

Domain configure: Enabled

Domain auto-reconfigure: Disabled

Fabric name: 48:33:43:2d:46:43:1A:1A

Priority: 128

Domain ID: 11 (preferred)

Principal switch running time information:

Priority: 1

Path Interface

Upstream Vfc1

Downstream Vfc2

The output shows that the domain configuration is complete and that the principal switch assigns

domain ID 11 to Switch A.
# Display the domain ID list of VSAN 1.

[SwitchA] display fc domain-list vsan 1

Domain list of VSAN 1:

Number of domains: 4

Domain ID WWN

0x01(1) 48:33:43:2d:46:43:1B:1B [Principal]

0x0b(11) 48:33:43:2d:46:43:1A:1A [Local]

0x0d(13) 48:33:43:2d:46:43:1C:1C

0x0e(14) 48:33:43:2d:46:43:1D:1D

This manual is related to the following products: