Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create a static CRLSP.
•
Configure the ingress node:
static-cr-lsp ingress lsp-name { nexthop
next-hop-addr | outgoing-interface
interface-type interface-number }
out-label out-label-value
•
Configure a transit node:
static-cr-lsp transit lsp-name in-label
in-label-value { nexthop next-hop-addr |
outgoing-interface interface-type
interface-number } out-label
out-label-value
•
Configure the egress node:
static-cr-lsp egress lsp-name in-label
in-label-value
Use one command according to
the position of a device on the
network.
By default, no static CRLSP
exists.
Do not configure the next hop
address as a local public IP
address when configuring the
static CRLSP on the ingress
node or a transit node.
You do not need to execute the
static-cr-lsp egress command
on the egress node if the
outgoing label configured on
the penultimate hop of the static
CRLSP is 0 or 3.
Displaying static CRLSPs
Execute display commands in any view.
Task Command
Display static CRLSP information. display mpls static-cr-lsp [ lsp-name lsp-name ] [ verbose ]
Static CRLSP configuration example
Network requirements
Switch A, Switch B, and Switch C run IS-IS.
Establish an MPLS TE tunnel over a static CRLSP from Switch A to Switch C.