Alert Notification
4 options are included in this item;
<OFF>: The Alert Notification is turned off.
<Event>: When the alarm is triggered, the DVR will send an alert message to
the CMS.
<Alive>: The DVR will send an alive message to the CMS every N second
just to show users that the connection between the DVR and CMS
is in effect. The time interval N can be adjusted in
<Both>: This enables the DVR to send both Event and Alive alert messages
to the CMS.
Alert IP
The Alert IP must match the IP address of the computer.
Alert Port
The ports for DVR and the CMS Alert MUST be the same.
Alive Interval
Users can define the time interval (1 to 255 seconds) between each alive
message. This item will not be accessible if the alert notification menu is set
to
< Event Full Screen >
This function allows the unit to display the alarm channel in full screen size when an alarm
is triggered.
Select
Monitor when an alarm is triggered; select
Monitor; and select
Monitor.
< Event Duration >
This item determines the duration of the buzzer and Alarm Out relay function once an alarm
is triggered. The available event duration range is from 5 seconds to 999 seconds.