1 call logging – Westermo IDW-90 AT User Manual
Page 89

89
6620-3200
9.1 Call logging
Within the trace module functionality the logging of ISDN connection attempts –
successful or not – can be selected (default).
The buffer is built as a wrap around buffer, if full, the oldest entries will be deleted.
The maximum number of entries is about 80.
Every entry is formatted in the following way:
EntryNo, dw(timestamp), int(TypeandSource), int(Length), Date, Time, int(Appl),
int(Service), Duration, int(State), Cause, ChargingInfo, ISDN-No.
For detailed information about the Disconnect cause refer to the chapter on ISDN
causes.
The following commands can be used:
trcmsk
0000000000000080
Enable call logging
trcread
Readout all available logging data
trcclr
Clear logging data
Examples:
Reset
00000 0000000002 FFFF
Outgoing Call, normal clearing:
00001 0000013349 8A80 002F 98/06/16 14:48 80 02
00:00:01 00 349F 0000 291
Outgoing Call busy:
00002 0000020676 8A80 002F 98/06/16 14:49 80 02
00:00:04 FF 3491 0000 500
Incoming Call, normal clearing:
00003 0000020875 0A80 002F 98/06/16 14:59 80 02
00:00:06 03 349F 0000 270