Westermo IDW-90 AT User Manual
Page 81

81
6620-3200
7.3.1 X.25 causes in Reset packet
00
Triggered by DTE
01
Out of operation (virtual connections only)
03
Remote sequence error
05
Local sequence error
07
Temporary network disturbance
09
Remote station ready (virtual connections only)
0F
Network ready (virtual connections only)
11
Incompatible destination
7.3.2 X.25 causes in Clear packet
Coding of the field “cause” in packet “Indicate-Cause”.
00
DTE/CONF
Triggered by the remote DTE/DCE
01
OCC
Remote DCE busy, dialed number busy/engaged
03
INV
Facility requested not valid/supported
05
NC
Temporary disturbance in network
09
DER
Remote DTE doesn’t answer/out of operation
0B
NA
Access not available
0D
NP
No access with this dial number
11
RPE
Remote procedural error, sequence error
13
ERR
Local procedural error, sequence error
19
RNA
Reverse charging not accepted
21
ID
Remote DTE/DCE incompatible
29
FNA
Incompatible connection request; receipt of single
packet not agreed upon
7.3.3 X.25 causes in Restart packet
Coding of the field “Reason for Restart” in the packet “Indicate-Restart”.
01
Local sequence error
03
Temporary disturbance in the network
07
Network ready