6620-3200
S210 – V.34 Symbol Rates (analogue)
The bits in this parameter control V.34 symbols rates and enables/disables V.34
asymmetric rates. This parameter is used for diagnostic purposes only.
Bits 0 – 2
Selects the range of allowed V.34 symbol rates.
Bit
Symbol Rates (baud)
2
1
0
0
0
0
2 400 only
0
0
1
2 400 only (no 2 734)
0
1
0
2 400, 2 800
0
1
1
2 400, 2 800, 3 000
1
0
0
2 400, 2 800, 3 000, 3 200
1
0
1
2 400, 2 800, 3 000, 3 200, 3 429 (default)
Bit 3
Enable/disable V.34 asymmetric rates.
0 = Disable asymmetric rates
1 = Enable asymmetric rates (default)
Bits 4 – 7 Reserved.
Default: 13.
Table 1 S-registers
Short Form Long Form
Description
Note
0
OK
A command line has been executed
1
CONNECT
Connection established
( rn = call number of remote site)
2
RING
Indicates an incoming call (SETUP received)
3
NO CARRIER
No synchronization (xx = ISDN error cause)
or if the the call was to an analogue destination.
Replaces BUSY and NO DIALTONE.
Dependent on ATXn setting. Also sent when
the modem auto-disconnects due to loss of
carrier.
4
ERROR
Illegal command or error that can not be
indicated otherwise e.g.
1. The command line contains a syntax error.
2. The modem cannot execute a command
contained in the command line, i.e., the
command does not exist or is not
supported. see register S93
3. A command parameter within the command
line is outside the permitted range.
5
CONNECT 1 200
has been established.
(V110 or analogue connection)
6
NO DIALTONE
No access to ISDN network (xx = ISDN error)
7
BUSY
Number engaged (xx = ISDN error cause)