Westermo IDW-90 AT User Manual
Page 48

48
6620-3200
catab – Automatic call table
With this command the priority table of automatic DTR and TxD calling number is
set-up.
The IDW-90 will call the numbers defined in order from catab1 to catab3 until a con-
nection is established. The character # is used as prefix to signal that the call shall use an
analogue connection.
catabx
nn set entry number x to receiver number nn.
catabx
-
clear entry number x
catabx
show entry number x
catab
show all entries
Maximum number of entries = 3
Maximum length of number = 20 digits.
In example below entry 1 tells IDW-90 to make a call using the analogue modem, while
entry 2 and 3 making ISDN –ISDN connections.
Example:
catab1 #00461661200
catab2 004616480250
catab3 0123987652
cato – Call timeout to abort
Time to abort a call if not successfully connected after n seconds.
n = 3..255, (default 15 s).
capa – Call pause
Automatic call: set a call pause for n seconds before next call attempt.
n = 0 .. 255, n=0 no call retry, (default 3s).
catry – Calls retry
Automatic call: max. no of tries of every number entry in catab.
n = 1 .. 255 (default 1)
ccts – CTS control
CTS control
0: CTS follows RTS
1: CTS always ON (default)
2: CTS follows DTR
See also 4.3 Serial status lines
cdcd – DCD control
DCD control
0: DCD always ON
1: DCD indicates a connection (default)
2: DCD follows DTR
3: DCD indicates link level established (X.31-D only)
See also 4.3 Serial status lines