Westermo IDW-90 AT User Manual
Page 69
69
6620-3200
*wiop – General IO parameters
This command set the IO parameters.
Syntax:
*wiop=
*wiop=?
*wiop?
Min trig pulse time in 10 ms increments [1-255].
This parameter sets the minimum time the pulse must be active.
A pulse shorter than this time will be skipped.
Max trig pulse time in 10 ms increments [1-255]
Sets the maximum active width of a pulse, if pulse is longer
the pulse will be skipped.
The number of pulses will be calculated when the time
between pulses is longer than 3 times tmin.
Trig source and type
0=NO
Trigger not used
1=LEVEL
Trigger source is the Digital input Level or edge sensitive
trigger
2=PULSE
Pulsed trigger used
3=DCD
Trigger internally coupled to reflect the DCD signal
4=DTR
Trigger internally coupled to reflect the DTR signal
0=NO
Trigger not used
1=HIGH
Defines that a High level triggers the service
2=LOW
Defines that a Low level triggers the service
3=POS
A positive edge triggers the service.
4=NEG
A negative edge triggers the service.
Trigger level
0=NO
Output not used
1=IO operation Controlled by remote IO Transparent or Out
2
Reserved
3=DCD
Output will be controlled by DCD. An active DCD
will activate the output.
4=DTR
Output will be controlled by DTR. An active DTR
will activate the output.
Normal inactivated state of the output as well as the source
controlling the output.