Westermo IDW-90 AT User Manual
Page 52
52
6620-3200
iinit – ISDN initialisation after power ON
Defines the behavior of the TA after Reset. If set to 1 the ISDN interface will automati-
cally be activated after Power ON. As a result, the LED L1 will show the correct state
regarding the ISDN line.
If set to 0, the TA stays passive to the ISDN line after power On, the LED L1 will stay
blinking until the first successful communication through the ISDN line takes place.
iinit 0:
no activation after Power On
iinit 1:
Automatic activation after Power On
iinit 2:
Automatic activation every time the S-Bus is deactivated
iinit 3:
Automatic Tei-Request after Power On
iinit 4:
Automatic Tei-Request and LAPD link setup after Power On
iinit 5:
Automatic Tei-Request and LAPD link setup and RESTART after
Power On (ISDN point to point mode, all connections will be
cleared)
iinit 6:
Automatic Tei-Request and LAPD link setup permanently
isdn – ISDN D channel protocol
Selects ISDN D channel protocol
0: DSS1 (Euro-ISDN) (default)
12: leased line with usage of just B channel B1.
13: leased line with usage of just B channel B2.
k – Windowsize
Layer-2 protocol: windowsize (default:7). k = {1..7}
Value will be automatically changed with changing B channel protocol.
lcgr – Logical group number X.25
Logical group number for X.25 packet layer protocol.
lcgr = {0..255}, default: 0
llc – Low layer compatibility
Low layer compatibility for outgoing calls (Hex bytes)
(see note 2 and 3, page 81)
load – Load stored parameter setting
All parameters stored in non volatile RAM will be loaded.
loadsw – load DIP-switches parameter setting
Parameters entered via the DIP-switches will be loaded and active in the same manner as
at power up.
msni – Multiple Subscriber Number for incoming calls
Own MSN (Multiple Subscriber Number) for incoming calls.
msni *
global msn, all incoming calls will be accepted. (default)
msni nn
set "msni" to nn = string of digits (max length = 22)
msni -
no acceptance of incoming calls
msni
show current setting of "msni".