Westermo IDW-90 AT User Manual
Page 54

54
6620-3200
racctab – Access table setup for remote access
Using these commands you can setup a table, to allow only dedicated callers for remote
management to get a connection to the IDW-90.
racctabx nn set entry number x to ISDN number nn
racctabx -
clear entry number x
racctabx *
Allow all incoming calls to be accepted
racctabx
show entry number x
racctab
Show all entries
Note: for a detailed description
see page 47
reset – Reset IDW-90
Resets the whole functionality of the IDW-90 by forcing a hardware reset.
ridle – idle data timeout for remote connection
Timer to disconnect the remote connection after inactivity (sec).
0:
inactive
1..n: delay time to disconnect in seconds (1..255).
60: 60 seconds (default)
ringtimer – Delay of RING messages
Delaytime between two RING messages, if S0 register is set not equal to 1, value in
100 ms. Default 50 (5 seconds).
rmsg – Message for remote access
Controls whether a message for establishment or
??
disconnect message on the remote
port, If display enabled “rmon” for established and “rmoff” for disconnected remote con-
figuration access is sent out on the remote local port.
??????????
0:
display no messages (default)
1:
display messages
rmsn – Multiple Subscriber Number for remote
MSN (Multiple Subscriber Number) for remote configuration
*: no specific MSN, all incoming calls accepted
rmsn *
global msn, all incoming remote calls will be accepted. (default)
rmsn nn
set "rmsn" to nn = string of digits (max length = 22)
rmsn -
no acceptance of incoming remote calls
rmsn
show current setting of "rmsn".
rstmsg – Startup message
Startup message:
"+++ Press
after start up can be displayed with a fixed speed of 9600 bps, 8 data bits, no parity,
1 stop bit.
0:
inactive, no startup message will be sent after power on. (default)
1:
active, startup message will be sent after power on