Westermo IDW-90 AT User Manual
Page 62

62
6620-3200
*wiol – General IO list
This command is used to program the list of IO entries with parameters and data.
The list can contain up to 10 entries
Syntax:
Set up a service entry:
*WIOL=
Request the format string:
*WIOL=?
*WIOL : (1-10), (0-7),(0-3), (0-255), (0-1), (0-20 char),
(0-160 char), (0-20 char), (0-2), (0-8 char), (0-20 char)
List all table entries. Listing will pause every 3rd entry and wait
for any key hit to continue. ESC will terminate.
*WIOL?
List entry 3.
*WIOL=3?
IO entry number, up to 10 entries can be defined.
IO entry service
0=NONE
No service defined for this entry
1=DIAL
Makes a connection to the number defined in
2=SMS
3=TEXT
Make a connection to number defined in
4=EMAIL
Reserved for future use, service not implemented.
5=OUT
Make a connection to the number defined in
output according to pattern defined in string defined in
The connection is terminated after the pattern is transferred.
6=CMD
AT command specified by
7=TRANS
Makes a connection to number defined by
between the two units. The transparent mode must be ended by a timeout.