Westermo IDW-90 AT User Manual
Page 63

63
6620-3200
Defines whether the establishment of service shall be retried, the
time between retries is controlled by register S7.
Timeout is used in Dial and Transparent IO. The timeout is designed
as an inactivity timer and will be retriggered for each Data / IO
transfer. The timeout is the only normal way to terminate Dial and
Transparent IO, see Table 5 for reference of state after termination
by timeout.
Setting a timeout for any other service than transparent IO will not
cause any failure but will not have any function.
Priority of the service specified.
0=NO
No retry, tries once to perform requested action
1=RETRY
Retry infinitely to establish service according to current table entry.
2=RETRY_3
Do 1 try and max 3 retries.
3=NEXT_OK
If current service ends with OK the service specified by next table entry
will be triggered.
If fail to perform/establish the current entry service the unit will return to idle.
4=NEXT_ERR The unit will execute service specified by next table entry if fail to
perform/establish current service.
If service according to current table entry terminates normally the unit will
return to idle and wait for any new event trigger.
Function of
= 0
The service will not be terminated
= 1 – 255
The timeout is specified in units of 10s.
Valid values 1 – 255 *10 s (10s – 2550s)
Function of
= 0
An existing connection will not be terminated.
Retries will be made according to setting of
is set by register S7.
= 1
The current connection will be terminated before the connection specified
by service is established.