Westermo IDW-90 AT User Manual
Page 15

15
6620-3200
&F – Load factory defaults
Factory default will be loaded, ISDN protocol setting and msn’s will not be overwritten.
(for storing in non volatile memory please use the command AT&W).
AT&F0
Setup all parameters concerning data port
AT&F1
Setup all parameters including ISDN protocol and msn settings.
!&F – Load factory defaults
Factory default will be loaded for the analogue option
(for storing in non volatile memory please use the command AT!&W).
AT!&F
The analogue modem loads the factory default configuration (profile)
H – Disconnect
Disconnects existing ISDN data connection, after issuing the Escape sequence (+++).
To enter the ATH command during an active data connection you must use the follow-
ing sequence "<1 sec pause> <+><+><+> <1 sec pause>" to reach the online command
mode.
The time gap between all three plus signs may not exceed 1 sec.
The escape sequence is transmitted transparently to the remote device.
The timeout after sending the "escape sequence" <+><+><+> will increase if the
configuration parameter "txfwd" will rise. The default value of "txfwd" is set to "0".
I – Display version information
Displays different information about version number and settings:
ATI0
Returns the “Modem”-type; name of the terminal adapter (“IDW-
90“)
ATI1
Returns internal checksum
(“??”)
ATI2
Returns “OK”
ATI3
Returns version string:
“410045vv”
vv = version number.
ATI4
Returns manufacturers name: “Westermo Teleindustri AB”
ATI5
Returns ISDN selected D-Channel protocol: “0 – DSS1”
ATI6
Returns copyright string: “(c) Copyright Westermo Teleindustri AB”
ATI7
Returns the status of the IDW-90 configuration switches.
1
1
1
1
“00000000.00000000.00000000.00000000”
SW1
SW2
SW3
SW4
‘0’ = switch OFF and ‘1’ = switch ON.
ATI9
Returns plug and play ID string
ATI99
Returns software version creation date