Westermo IDW-90 AT User Manual
Page 66

66
6620-3200
Table 5 Dial and Transparent IO connection types
Connected Data 1
prio
Line Type
No
Empty
No
LL
Illegal.
No
Empty
Yes
LL
Illegal.
No
Number No
LL
Illegal.
No
Number Yes
LL
Illegal.
Yes
Empty
No
LL
Normal Transparent IO over leased line.
See Note 1
Yes
Empty
Yes
LL
Normal Transparent IO over leased line.
See Note 1
Yes
Number No
LL
Normal Transparent IO over leased line,
number discard. See Note 1
Yes
Number Yes
LL
Normal Transparent IO over leased line,
number discard. See Note 1
No
Empty
No
CS
Error, try to establish service failed.
No
Empty
Yes
CS
Error.
No
Number No
CS
Normal Transparent IO over Circuit switched.
line
No
Number Yes
CS
Normal Transparent IO over Circuit switched.
line
Yes
Empty
No
CS
Use current connection for I/O transfer.
The Empty data 1 will override priority.
See Note 1
Yes
Empty
Yes
CS
Use current connection for I/O transfer.
See Note 1
Yes
Number No
CS
Due to that line is busy and no priority set
the modem will retry connection according
to
Yes
Number Yes
CS
Disconnect and dial Number.
LL = Leased line PSTN or ISDN
CS = Circuit switched PSTN, ISDN or GSM
Note 1 The existing data connection will be paused during transparent IO transfer.
The modem will use the flow control specified by flow control command. If no
flow control set DTE data will be discarded during the Transparent IO transfer.
When the transparent IO transfer is terminated by timeout the connection will
revert to data-mode and activate CTS / sending XON.