Westermo IDW-90 AT User Manual
Page 55

55
6620-3200
rsttim – Startup timer
Startup delay timer after reset. Within this period the configuration can be entered after
reset.
1 .. 255 :
reset phase in 100 milliseconds, default: 40 (4 seconds)
rsub – Subaddress for remote access
SUB (sub address) for remote configuration
*: no specific SUB, all incoming calls accepted (default).
rsub *
global SUB, all incoming remote calls will be accepted, (default).
rsub nn
set "rsub" to nn = string of digits (max length = 22)
rsub -
no acceptance of incoming remote calls
rsub
show current setting of "rsub".
Note: The remote connection needs to get an incoming call with a special LLC value "88
90 21 58 00 BB" which is automatically set in the additional "e" of the dial com-
mand from the connecting IDW-90.
save – Store parameter changes
Stores the actual set of parameters in non volatile memory.
sbits – Number of stopbits.
Sets the number of stopbits 1 or 2, (1 default).
sertrc – serial link trace
Controls the part of serial output to the trace module.
bit 0 :
enable serial data to the trace log.
bit 1 :
enable serial status lines to the trace log.
available values: 0, 1, 2, 3
(Default 3, enable serial data and status lines).
show – Show parameters
Displays the actual set of parameters, see &V1.
showall – Show all parameters
Displays all the accessable parameters
status – Status of serial line and ISDN
Returns the status of the serial line and ISDN channels.
Example: current status information IDW-90
Current status information IDW-90
serial line: DTR:on, RTS:on, DSR:on, CTS:on, DCD:off, RI:off
ISDN: L1:down
Dch: Prot:DSS1 State:disconnected, CdPN:, CgPN:, prev error: 0
Bch: Prot:X.75 SLP State:disconnected, CdPN:, CgPN: