Welltech LP-803 v.3.07 User Manual
Page 75

LAN Phone 803
User Manual
Welltech Technology Co., Ltd.
75 / 90
2014/07/22
Step 1: The filename for checking firmware version, the filename is according to [Firmware File
Prefix] on [Auto Update Setting] and adds [_ver.dat ] to be [filename_ver.dat], (See Figure
1).
Ex:Firmware File Prefix: PHONE, the filename for checking firmware version is
TA1S_ver.dat.
Pay attention to [Firmware File Prefix], the name must be the same with ***_ver.dat.
(Figure 1)
Step 2: After build a [PHONE_ver.dat] file, there must have [CPU, CNAME] two data to compare
with updating file in Server. If the Server one is newer than your existing one, then your
LP803 will update firmware, (See Figure 2).
(Figure 2)
Note:
CPU: The date of updating file, it can only enter numbers.
CNAME: The updating filename, please enter a complete name without space or signs.
Step 3: Please place
***_ver.dat
and
*.ssh
files in the designated folder of the Server.
Example 2: Check New Firmware Type
Check New Firmware Type: Scheduling only (Upgrade Automatically)
Step 1: In [Auto Update Setting] web page, Set up [Update Active: HTTP, HTTP Server:
192.168.50.2, HTTP File Path: /HFS/, Check New Firmware Type: Scheduling only,
Scheduling (Date): 14, Scheduling (Time): AM 00:00-05:59, Automatic Update: Automatic,
Firmware File Prefix: PHONEO] (See Figure 3).