*Special Applications: Door control board connection.

1. This feature requires to produce a different phone line cable.
2. Line 1、Line 2 are relay’s second set of contacts (Connected to relay the same pin), Line 3、
Line 4 are relay’s first set of contacts (Connected to relay the same pin). In use time, these
contacts will reference web page setting, They have Normal Open(

Always open

) or Normal

Close(

Always short

) status.

3. Please use the two contacts to connect door control board PCBA. Than user can use this
LP803 to control door access devices.

Note. Reference Page 85, Management > Advanced table item 『Relay Control』 and 『Relay
Mode』Explanation.

1.5.1. Network Environment Setting


Netwrok Mode: Default NAT Mode
WAN Port: DHCP Client Mode

LAN Port: DHCP Server Enable, IP Address: 192.168.123.1, Mask: 255.255.255.0


1.5.2. Connection

Please connect the personal computer to LP803 LAN port, then set up computer Ethernet to

configure DHCP mode. The computer will get DHCP IP address. (ex. 192.168.123.150). Use Web
browser at your computer at

http://192.168.123.1:9999

to enter webpage setup mode of LP803.