240
Transmission Modes
WAVECOM Decoder W61PC/LAN Manual V7.5
Parameter
Value
Receiver settings
FM, BW = 12 kHz
Input format(s)
AF, IF
If more than two identical digits are to be transmitted, the repetition tone is appended to the digit tone
(e.g. 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition tone).
In most systems the accuracy of the single frequencies has to be within +1/-1.5% of the nominal value.
For ZVEI modes having nominal tone durations of 70 ms, the duration of a single tone may vary ± 15 ms.
Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the Options menu a Time stamp function can be ena-
bled to add date and time to each call.
Tone Allocation
Digit
Hz
Digit
Hz
0
2200
8
1830
1
970
9
2000
2
1060
A
2600
3
1160
B
2800
4
1270
C
810
5
1400
D
886
6
1530
E
2400
7
1670
Tone duration: 70 ms
ZVEI-3
The entire call number is transmitted by consecutive tones in decade sequence. When two identical digits
are to be transmitted consecutively, then an eleventh frequency is used as a repetition identifier.
Parameter
Value
Frequency range
VHF/UHF
Operation modes
Analogue selcal
Receiver settings
FM, BW = 12 kHz
Modulation
FM, SUB Tone
Input format(s)
AF, IF
If more than two identical digits are to be transmitted, the repetition tone is appended to the digit tone
(e.g. 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition tone).
In most systems the accuracy of the single frequencies has to be within +1/-1.5% of the nominal value.
For ZVEI modes having nominal tone durations of 70 ms, the duration of a single tone may vary ± 15 ms.
Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the Options menu a Time stamp function can be ena-
bled to add date and time to each call.
Tone Allocation
Digit
Hz
Digit
Hz
0
2200
8
1830