beautypg.com

Wavecom W61PC V7.5.0 User Manual

Page 156

background image

146

Transmission Modes

WAVECOM Decoder W61PC/LAN Manual V7.5

EEA

The entire call number is transmitted by consecutive tones in decade sequence. When two identical digits
are to be transmitted consecutively, then an eleventh frequency is used as a repetition identifier.

Parameter

Value

Frequency range

VHF/UHF

Operation modes

Analogue Selcal

Modulation

FM, SUB Tones

Receiver settings

FM, BW = 12 kHz

Input format(s)

AF, IF

If there more than two identical digits are to be transmitted the repetition tone is appended to the digit
tone (e.g. 22222 is transmitted as f2 fw f2 fw f2, where f2 is the tone for "2" and fw is the repetition
tone).

In most systems the accuracy of the single frequencies has to be within +1/-1.5% of the nominal value.

Decoding the selective calls is started by clicking on a system. If transmission and system selection con-
form, the call sign is displayed on the monitor. In the Options menu a Time stamp function can be ena-
bled to add date and time to each call.

Tone Allocation

Digit

Hz

Digit

Hz

0

1981

8

1747

1

1124

9

1860

2

1197

A

1055

3

1275

B

930

4

1358

C

2400

5

1446

D

991

6

1540

E (REPETITION)

2110

7

1640

Tone Duration: 40 ms

EFR

A German company operates a radio broadcast load balancing and ripple control system for electrical
power distribution networks. Short telegrams are used to control street lights, heaters, tariff switching etc.

Parameter

Value

Frequency range

HF

Operation modes

Broadcast asynchronous ASCII

Modulation

FSK

Shift/Bandwidth

340 Hz

Symbol rate

200.0 Bd

Receiver settings

DATA, CW, LSB or USB

Input format(s)

AF, IF

This manual is related to the following products: