Verilink WANsuite 5230 (34-00304.F) Product Manual User Manual
Page 166
4-50
W A N s u i t e 5 2 6 0 / 5 2 3 0
Figure 4.42
Network Interface Test Details Screen
BERT Table on the Network Interface Test Details Screen
The BERT table lets you set the test parameters listed below.
Setting
Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.
Values: Net, Use Service, Idle, Channel 1...31
Default: Net
BERT Pattern
Specifies the pattern to be transmitted during a test for the selected port.
Values: Marks, QRSS, 511, 2047, 2
15
, Spaces
Default: QRSS
NOTICE:
The 2
15
pattern is the ITU (European) version, not the ANSI version.
Test Duration
Specifies the length of time for which the test should run for the selected port.
Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes
Service Index
Selects the channels with a service to BERT (refer to the "Service Table
Screen" on page 4-19).
Rate
Sets the bit rate to BERT for each selected channel. If “Nx64K” is selected,
the ones density requirements of the E1 network line must be ensured. If
“Nx56K” is selected, ones density for the selected DS0 channel is maintained.
Values: Nx56K, Nx64K
Default:Nx64K
Pattern Sync
Displays the state of pattern sync during a test. If no test is in progress, “No
Test” is displayed. If a test is active, but the receiver is not in pattern sync,