TASCAM SS-CDR200/SS-R200/SS-R100

3 Select

OTHERS

.

4 Press the MULTI JOG dial or , [LOCK] button (or

remote control ENTER or t button) to open the

REC OTHERS

screen.

5 Select

SRC

.

6 Press the MULTI JOG dial or , [LOCK] button (or

remote control ENTER or t button) to move the

cursor right to select the value.

7 Turn the MULTI JOG dial (or press the remote

control 5 and b buttons) to set it to

ON

(default

value:

OFF

).

8 When you have finished making the setting, press

the HOME/DISPLAY button (or remote control

HOME/DISP button) to return to the Home Screen.

NOTE

• If a digital signal with a sampling frequency that

differs from the sampling frequency specified in the

REC FORMAT

item is being received at the DIGITAL

IN jack, and you attempt to record with

SRC

off, an

FS

UNMATCH

error message will appear.

• The sampling rate converter (SRC) setting is retained

even after the power is turned OFF.

Monitoring the input signal

When you press the front panel or remote control

RECORD button to enter recording standby, the RECORD

and READY buttons light, and the input signal will be

output from the various output jacks (headphones, analog

balanced, analog unbalanced and digital). In addition, the

meters on the home screen will show the input level.
To end recording standby, press the front panel or remote

control STOP button.

TIP

• If you simply want to monitor the input signal without

intending to record anything, press the RECORD key

without any media in the current device.

MONITOR

will

appear on the display, and the RECORD button will

blink red.

• To stop monitoring the input signal, press the STOP

button on the front panel or remote control.

Adjusting the input signal level and

balance

You can use the menu to adjust the level and balance of

the input signal.
Follow the instructions in the “Monitoring the input

signal” section above to enable monitoring of the input

signal, and then follow these procedures.

1 Press the MENU [JOG] button (or remote control

MENU button) to open the

MENU

screen.

2 Open the

REC

menu.

3 Select

INPUT VOLUME

.

4 Press the MULTI JOG dial or , [LOCK] button (or

remote control ENTER or t button) to open a pop-

up with the

INPUT VOLUME

settings.

5 Set the following

INPUT VOLUME

items.

LEVEL
Adjust the input level.
Options:

–inf

,

–54dB

0.0dB

(default value) –

+18dB

BALANCE
Adjust the input balance.
Options:

L50

C

(center, default value) –

R50

NOTE

• The level meter will show

OVER

at

–0.2 dBfs

.

• Since the level meter appears on the Home Screen at

the top of the display, you can check the input level as

you adjust it. Set the level as high as possible without

making the

OVER

indicator to the right of the meter

appear.

6 When you have finished making the setting, press

the HOME/DISPLAY button (or remote control

HOME/DISP button) to return to the Home Screen.

NOTE

The input

LEVEL

and

BALANCE

settings are retained even

after the power is turned OFF.

Basic recording operations

You can begin recording after you have finished making

the above settings (input source selection, recording file

format setting, sampling rate converter ON/OFF, input

level adjustment).
To start recording standby from a stopped state:
Press the front panel or remote control RECORD button

to put the unit in recording standby (The RECORD and

READY buttons light).
To start recording from recording standby:
Press the front panel or remote control PLAY button.
To switch from recording to recording standby:
Press the front panel or remote control READY button.

5 – Recording