Multiple Earth connections:
76
Multiple Earth connections:
In general, multiple earth connections to an EUT (e.g. water pipe
connections to a water heater) can cause difficulties in measurement.
This has previously needed the additional earth connections to be
isolated.
The Supernova Elite tester is capable of testing earth connections in
the presence of additional earth paths. This is done automatically by
performing a point to point measurement of the earth connection, and
measurement of the differential leakage current, rather than the earth
lead current. Measurements are thus assured without special
precautions.
Barcodes
Barcode Scanner Specification
The Supernova Elite Tester can be used with barcodes and barcode
scanners, readers or wands compatible with other Seaward PAT
testers These connect to the serial (RS232) connector The required
barcode reader / scanner configuration is as follows:-
Baud Rate:
9600
Start Bits:
2
Data Bits
8
Stop Bits:
2
Parity:
None
Inter-character Delay: 20ms
When to use a Barcode Scanner
Barcodes can be scanned at the following points:-
• Entering a Testcode as part of an Automatic Test in the ENTER
TESTCODES screen
• Entering a Testcode in the TEST SETTINGS EDITOR
• Entering an Appliance number in the ENTER APPLIANCE
DETAILS screen.