beautypg.com

C2648 prodigy and prodigy plus service manual – Scotsman C2648 User Manual

Page 63

background image

C2648 Prodigy and Prodigy Plus Service Manual

January 2015

Page 63

Electrical Shock Hazard
Disconnect electrical

power before beginning

Purge Valve or Water Level Sensor

Purge valve
1. Push and hold the Off button to shut the machine off.
2. Disconnect electrical power.

3. Remove front panel.
4. Unplug wires from valve coil.
Note: The coil can be removed from the valve body

by rotating it 1/8 turn CW. After removal of the coil

the spring and plunger can be taken out.
5. Loosen screws holding valve bracket to mounting

bracket (circled area in photo).

6. Remove inlet and outlet hoses
7. Lift the valve and bracket up and off the keyhole

slots. Remove valve from cabinet.

8. Remove valve from bracket.
9. Reverse to reassemble
10. Push and release the On button to restart the machine

Water level sensor
1. Push and hold the Off button until the machine shuts

off.

2. Remove the front panel.
3. Locate water level sensor.
4. Squeeze the locking tabs together and pull the

sensor up and out of the sump.

5. Unplug the electrical connection from the sensor.
6. Reverse to reassemble.