Electrical Component Details

Compressor
• Operated by the compressor contactor.

Contactor
• Operated by the controller and the high pressure cut out switch. Line voltage coil. When energized the

Compressor indicator light will be ON.

Water Pumps
• Operated by the controller, one of them thru a NC relay. When the Pump light is ON during a Freeze cycle,

both pumps should be operating. When the Pump and Purge lights are both ON, one pump will be ON and

one will be OFF.

Inlet Water Solenoid Valve
• Operated by the controller. Line voltage coil. When energized, the Water Solenoid indicator light will be ON.

Purge Valve
• Operated by the controller. Line voltage coil. When energized, the Purge Valve indicator light will be ON.

Energized for a time during harvest.

Fan Motor
• Remote condenser fan motor is on whenever the compressor is.

High pressure cut out
• There is a high pressure cut out switch that shuts the power off to the compressor contactor if the

discharge pressure is too high. It is an automatic reset.

Harvest Assists - Originally solenoids later units have motors

• Operated by the controller through a relay. In parallel with the hot gas valve. Cycles on and off at the

beginning of a restart. Energized throughout the harvest cycle. Line voltage coil.

Liquid Line Valve
• Opened by the controller to start a freeze cycle. Closed to shut unit off. Line voltage coil.

Hot Gas Valves
• Operated by the controller through a relay. In parallel with the harvest assist. Cycles on and off at the