Coupling Instructions

The couplings on the ends of the pre-charged line

sets are self-sealing when installed properly.
Follow these instructions carefully.
These steps must be performed by an EPA Certified

Type II or higher technician.
Initial Connections
1. Remove the protector caps and plugs. Wipe the

seats and threaded surfaces with a clean cloth to

remove any possible foreign matter.

2. Lubricate the inside of the couplings, especially

the threads and O-rings, with refrigerant oil.

3. Position the fittings on the correct connections on

the condenser and ice machine.

• Connect the 5/8” discharge line to the remote

condenser fitting.
• Connect the 1/2" liquid line to the remote condenser

fitting.
• Connect the discharge line to the ice maker fitting.
• Connect the 1/2" liquid line to the ice maker fitting.
Final Connections:
4. Tighten the couplings together by hand until it is

certain that the threads are properly engaged.

5. Hold the tubing from rotating with one wrench and

tighten each coupling swivel nut with another until

it bottoms out or a definite increase in resistance

is felt.

It is important that ONLY the nut on the pre-charged

tube be turned, or the diaphragms will be torn out

by the piercing knives and they will be loose in the

refrigeration system.
Note: As the couplings are tightened, the

diaphragms in the quick connect couplings will

begin to be pierced. As that happens, there will be

some resistance to tightening the swivel nut.
6. Mark a line on the coupling nut and unit panel.

Then tighten the coupling nut an additional one-

quarter turn. The line will show the amount that

the nut turns. Do NOT over tighten.

7. Check the couplings for leaks after all connections

have been made, and after the king / liquid outlet

valve has been opened (do not open at this time).