beautypg.com

C2648 prodigy and prodigy plus service manual – Scotsman C2648 User Manual

Page 14

background image

C2648 Prodigy and Prodigy Plus Service Manual

January 2015

Page 14

Electrical

The machine is not supplied with a power cord, one

must either be field installed or the machine hard-

wired.
The dataplate on the back of the cabinet details

the power requirements, including voltage, phase,

minimum circuit ampacity and maximum fuse size.
HACR type circuit breakers may be used in place of

fuses. Extension cords are not permitted. Use of a

licensed electrician is recommended.
The ice maker is designed to operate on its own

electrical circuit and must be individually fused.
Voltage variation must not exceed the limits listed

earlier.
The remote condenser is designed to be powered

from the ice machine. A separate knockout hole has

been provided near the ice maker electrical junction

box.

Electrical connections are made inside the junction

box in the back panel of the ice machine.
1. Remove the junction box cover and route the

power cord through the access hole and properly

attach the power supply wires to the leads in the

junction box.

2. Attach the remote condenser fan motor wires to

the wires in the junction box tagged “fan motor

leads”.

3. Install field supplied strain reliefs per code. Attach

a ground wire to the ground connection in the

junction box.

4. Check voltage when complete.
5. Return the junction box cover to its original

position and secure with the original screws.

Follow all applicable local, state and national codes.

Remote

Condenser

Electrical

Connection

Power

Supply

Electrical Connections