Adjustments

Bridge Thickness - For A Service Tech Only
1. Push and hold Off till the machine stops.
2. Remove evaporator cover.
3. Remove left curtain.
4. Use a box wrench and rotate the bridge thickness

adjustment screw in 1/8 turn increments CW

to increase bridge thickness. Rotate CCW to

decrease bridge thickness.

Caution: Do not make the bridge too thin or the

machine will not harvest properly. Bridge thickness

adjustments are not covered by warranty.
5. Return curtain to its normal position.
6. Push and release the On button. Check next

harvest of ice. Repeat steps 1-6 if needed.

Water purge setting
The water purge is factory set to the automatic

position, suitable for most water conditions. The

setting can be changed to one of 5 manual settings or

left on automatic.

purge

setting

1 - Minimum

2 - Moderate 3 - Standard

4 - Heavy

5 - Maximum A - Automatic

Water

Type

RO water or

equivalent

Factory

Setting for

typical water

High TDS

water

Any with

conductivity not

less than 10

microSiemens/cm

To set:
1. Switch the machine OFF by holding the Off button

in until a number or the letter A shows on the

display.

2. Press and release the On button repeatedly until

the number on the display corresponds to the

desired setting.

3. Press and release the Off switch again to return to

the normal control state.

Ice Thickness Sensor

Ice Bridge Thickness Measurement

Too Big

Just Right,

Small Cube

Just Right,

Medium Cube

Too Small

1/8 to 3/16” bridge