beautypg.com

C2648 prodigy and prodigy plus service manual – Scotsman C2648 User Manual

Page 13

background image

C2648 Prodigy and Prodigy Plus Service Manual

January 2015

Page 13

Plumbing Requirements

All models require connection to cold, potable water.

A hand actuated valve within site of the machine is

required. There is a single 3/8” flare nut inlet water

connection, and a 3/8” to 3/8” flare union is supplied

with the machine and can be used if desired.
Water Filters
Install a new cartridge if the filters were used with a

prior machine.
Drains
All models require drain tubing to be attached to them.

There is a single ¾” FPT drain fitting in the back of the

cabinet.
Install new tubing when replacing a prior ice machine,

as the tubing will have been sized for the old model

and might not be correct for this one.

1. Connect water supply to water inlet fittings.
2. Connect drain tubing to drain fitting.
3. Route the drain tubing to building drain. Follow

local codes for air gap.

4. Use rigid drain tubes and route them separately –

do not Tee into the bin’s drain.

Vent the reservoir drain. A vertical vent at the back of

the drain, extended about 8 – 10” will allow the gravity

drain to empty and also keep any surges during

draining from discharging water.
Horizontal runs of drain tubing need a ¼” per fall per

foot of run for proper draining.
Follow all applicable codes.

Water Inlet

Connection

Potable Water

Supply

Optional Water

Filters

Reservoir Drain,

Venting Required

Floor Drain

Water Supply and Drain Connections