This light will be ON when the Purge Valve is ON.

Inlet Water Solenoid Valve

Test using the controller’s indicator lights.
1. Shut unit off by holding the Off button for 3 seconds. Wait four minutes.
2. Push and release the On button, observe the Water Solenoid indicator light. After the unit drains the

reservoir, the inlet water valve will be powered to refill the reservoir. When it gets power, the indicator light

will be ON. If the water valve does not open to fill the reservoir when its indicator light is on, do a voltage

check.

3. Shut the unit down by holding the Off button in for 3 seconds.
4. Unplug the harness connection from the inlet water valve. Wait four minutes.
5. Push and release the On button to restart the machine. After the unit drains the reservoir, the inlet water

valve connection should receive full voltage. If it does, the inlet water valve should be replaced. If there is

no voltage, check voltage from the controller. The inlet water solenoid valve pin is 7.

Test using an ohmmeter.
Disconnect electrical power. Unplug coil from harness. Measure coil resistance. If open, replace the inlet water

solenoid.