Problem

Likely Cause

Probable Solution

No power to unit

Power disconnected

Check breaker or fuse. Reset or

replace, restart and check

No power to controller

Transformer open

Replace transformer

Shut down on max. water fill time

Water shut off

Restore water supply

Shut down on maximum freeze

time

Water leak

Check purge valve, curtain, sump,

pump hose

Dirty condenser

Clean condenser

Restricted location, intake air too

hot

Have condenser moved

Ice thickness sensor dirty or

disconnected

Check ice thickness sensor probe

Water distributor dirty

Remove and clean water

distributor

Inlet water valve leaks through

during freeze

Check inlet water valve

Connected to hot water

Check for bleed thru from / missing

check valve in building water

supply

Incomplete harvest

Check harvest system

High pressure cut out opened

Check check fan motor
Check quick connects for complete

piercing

Fan motor not turning

Check fan motor, check fan blade

Water pump not pumping

Check pump motor, check

controller using test mode

Pump hose disconnected

Check hose

Liquid line valve does not open

Check coil of valve, check

controller using test mode.

Compressor not operating

Check compressor contactor,

check controller using test mode

Diagnostics