Ice Thickness Sensor

1. Test using the controller’s indicator light. Observe the Ready To Harvest light. Shut the machine off. Use

a wire to connect the metal part of the Ice Thickness sensor to the evaporator or simply remove the Ice

Thickness Sensor and touch its metal surface to the metal control box wall. The Ready for Harvest light

should go ON.

2. Test with an Ohmmeter. Disconnect electrical power. Open the control box cover. Unplug the ice thickness

sensor lead from the controller. Connect an ohmmeter lead to the ice thickness sensor lead, touch the

other ohmmeter lead to the ice machine chassis. There must be an open circuit. If there is continuity, the

sensor must be replaced. If there is no continuity, touch the ohmmeter lead to the metal part of the ice

thickness sensor. There should be continuity. If open, check the ice thickness sensor for scale build up.

Clean and recheck. If still open, replace the ice thickness sensor.

3. Test the controller’s ice thickness sensor circuit by connecting a wire from J10 to ground. Reconnect

electrical power. The Ready for Harvest light should go ON

Ice Thickness Sensor, contact

with water triggers Ready To

Harvest light

Ready to Harvest Light