Initial Start Up

Remove front and left side panels. Check machine

for any packing or wires rubbing moving parts. Note

location of control board in lower left corner of the

machine’s front.
1. Switch on the electrical power to the machine.
2. Observe that some of the control’s indicator lights

glow and its display shows O.

3. Wait 4 hours for the compressor’s crankcase

heater to warm up the oil in the compressor.

1. Open the water supply valve.
2. Turn the receiver’s outlet valve to the full open

position.

3. Push and release the ON button of the

lower left

corner switch panel.

The indicator light will begin to blink F. The purge

valve will open and the water pumps will start.

The inlet water valve will open to add water to the

reservoir. After a few seconds the purge valve will

close and the water pumps will stop. Water will flow

into the machine until the reservoir is full. The hot

gas valves and harvest assist devices will activate

and the liquid line solenoid valve will open, then the

compressor, remote fan motor and water pumps

will start. The display will show a continuous F. Five

seconds later the hot gas valves will close and the

harvest assist devices will return to their standby

positions. Warm air will be discharged from the

condenser coil.
4. During the Freeze cycle move each curtain to

confirm the controller is getting the signal from the

curtain switch. Two of them will cause the SW1 or

SW2 light on the control board to blink ON when

the curtain moves away from the evaporator and

OFF. One of the curtains will cause the period in

the display code to blink ON when the curtain is

moved away and OFF when returned to its normal

position.

5. Note: Moving the curtain during the Freeze cycle

has no affect on unit operation.

6. Observe the Ready for Harvest indicator light. It

may blink early in the freeze cycle, that is normal.

The control will ignore that signal for the first 6

minutes of freeze.

7. When the ice has frozen enough, the Ready for

Harvest indicator light will be on steady. After it’s

been on steady for a few seconds Harvest will

begin.

The display shows an H. The hot gas valves open

and the harvest assist mechanisms are activated.

The purge valve opens to drain some water, when it

does the inlet water valve opens to refill the reservoir.

After a few seconds the purge valve closes but the

inlet water valve continues to fill the reservoir. Harvest

continues until the ice is released as a unit from each

evaporator and forces each curtain to open.
8. When all curtains have opened and re-closed the

controller returns the unit to a freeze cycle.

9. Check the ice harvested for proper bridge

thickness. The ice bridge is factory set at 3/16

inch. If needed, adjust bridge thickness. Do NOT

make it too thin.

10. Determine the water purge setting from the table

on the next page. If desired, change the setting to

accommodate the local water conditions.

11. Return the panels to their normal positions and

secure them to the machine.

12. Instruct the user in the operation of the machine

and its maintenance requirements.

13. Fill out and mail the warranty registration form or

go on line at Scotsman’s website, www.scotsman-

ice.com and register it there.

Typical Ice Making Cycle Times (minutes)

Model

70

o

F. cond air /

50

o

F. water

90

o

F. cond air /

70

o

F. water

C2648R

11 - 13

13 - 15

Listed times are for clean machines. Cycle times at