Scotsman C2648 User Manual
Page 32

C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 32
Component Indicator Light Table
System
Indicator Light ON
Condenser Fan or Liquid Line Valve
LLV open
Water Pump
Pump Motor Powered
Purge Valve
Purge Valve Opens
Inlet Water Solenoid Valve
Inlet Water Valve Opens
Hot Gas
Hot Gas Valve Opens
Compressor Contactor
Contactor Closes
Ready to Harvest
Water contacting ice thickness sensor probe
Sump Empty
Open between mid sensor and common
Sump Full
Closed between top probe and mid probe
Curtain Switch
Curtain open
See also other documents in the category Scotsman Equipment:
- Prodigy Plus D Series (23 pages)
- C1030 (23 pages)
- Prodigy Plus D Series Remote Condenser Modular Cuber (26 pages)
- N1322 (54 pages)
- DC33 (26 pages)
- C1848 (22 pages)
- C2148W (25 pages)
- C2148R (26 pages)
- CU3030 (104 pages)
- EH430 D (31 pages)
- N1322 (24 pages)
- N1322 (18 pages)
- N1322L (18 pages)
- AFE424 (15 pages)
- AFE400 (25 pages)
- C2648R (25 pages)
- CU0920 (17 pages)
- CU0920 (31 pages)
- CB1030 (43 pages)
- CU3030 (18 pages)
- CU50 (16 pages)
- FME804 Installation (16 pages)
- FME804 Installation (32 pages)
- NB1322 (37 pages)
- HD30 (18 pages)
- HID540 Service Manual (41 pages)
- HID540AW (20 pages)
- MDT4F12 (16 pages)
- SCCP30 (15 pages)
- SCCP30 (30 pages)
- SCN60 (18 pages)
- SCN60 (38 pages)
- MDT5N40 (16 pages)
- TDE650 (33 pages)
- SCR33 (20 pages)
- ECC1800 (4 pages)
- SCCP50 (33 pages)
- SCV32 (16 pages)
- 2000 Prodigy Eclipse (50 pages)
- EH222 with ECC (57 pages)
- Nugget Ice Machines (22 pages)
- CME650 (24 pages)
- CD200 (19 pages)
- CME1656 (43 pages)
- CME456 (42 pages)