beautypg.com

C2648 prodigy and prodigy plus service manual – Scotsman C2648 User Manual

Page 5

background image

C2648 Prodigy and Prodigy Plus Service Manual

January 2015

Page 5

Product Description, Electrical Requirements

Ice Machine

Dimensions

w” x d” x h”

Model

Electrical

Use

condenser

Minimum

Circuit

Ampacity

Maximum

Fuse* Size

Suggested

Fuse* Size

48 x 28 x 31 C2648SR-3

208-230/60/3 PRC241-32A 21.6

30

30

same

C2848MR-3

208-230/60/3 PRC241-32A 21.6

30

30

Remote Condenser Footprint: On center mounting hole spread: 27.57” w x 33.38” d. See page 5.
Minimum bin top opening: 20.5” x 40.5” includes drop zones and ultrasonic sensor location. See page 5.
*Or HACR circuit breakers.
Table notes: Series revision code omitted. All the

listed condensers include a headmaster valve.
Ratings include the remote condenser motor, as it

is designed to be powered by the ice machine. If

connecting remote condenser independently of the

ice machine, use the information on the condenser's

dataplate for fuse and wire sizes.
Condensers are UL listed for these model ice

machines.

Central Condenser (Rack) Coils
The ice machine may be connected to a central

condenser coil. The requirements are:
• Coil – not previously used with mineral oil system.

Virgin coil preferred.
• Correct size (internal volume) and capacity (BTUH).

Contact Scotsman for data.
• Includes a headmaster valve for discharge pressure

control rated at 217 PSIG.
• Fan motor on all the time or controlled to be on

whenever the ice machine is operating.
• U.L. listed for the ice machine
• Non-Scotsman condensers must have prior

Scotsman Engineering approval for warranty

coverage to be in effect.