Pressure switch

High pressure cut out. The high pressure cut out switch will open at a preset pressure, shutting off power to

the compressor contactor. After the pressure has fallen to another preset level, the switch will re-close and the

contactor coil will be energized.

To Test High Pressure Switch:
A. Attach refrigeration gauge set to high side port.
B. Disconnect leads to fan motor.
C. Measure voltage at high pressure control.
D. Switch ice machine on, observe pressure that the pressure control opens at, compare to spec. Allow system

to equalize, observe the pressure that the pressure control closes at, compare to spec.

Transformer
Check secondary voltage, it must be between 10 and 15.5 AC volts. Replace if no voltage is output or if above

or below the acceptable voltage..

Controller
The controller’s software operation is confirmed if it is functioning. Execute the test to confirm its operation of

the loads. Illumination of a diagnostic code (other than E) is not an indication of controller failure. Each code

requires its own diagnosis.