C2648 prodigy and prodigy plus service manual – Scotsman C2648 User Manual
Page 61

C2648 Prodigy and Prodigy Plus Service Manual
January 2015
Page 61
Electrical Shock Hazard
Disconnect electrical
power before beginning
Contactor or Controller
Contactor
1. Disconnect electrical power.
2. Remove front panel.
3. Open control box cover.
4. Remove right side of control box.
5. Remove metal barrier from control box
6. Remove mounting screws holding contactor to control box.
7. Exchange wires from old controller to new. Refer to wiring diagram as needed.
Reverse to reassemble.
Controller
1. Disconnect electrical power.
2. Remove front panel.
3. Open control box door.
4. Unplug all wires from controller.
5. Remove screws holding controller to door
6. Push controller snaps down and pull controller frommounting bracket.
7. Before touching new controller, discharge any static electricity by touching the metal surface of the ice
machine cabinet.
8. Rotate selector switch to the proper model number for the machine the controller is being installed on.
9. Install new controller on mounting bracket, secure with original screws.
Note: Be SURE the controller is snapped into place and all screws returned to their original spots.
10. Attach all wires removed.
11. Shut control box cover.
12. Switch on the electrical power.