Controller Information

Machine Indicator Lights
• Power
• Status
• Water
• Clean

Code Display

Main codes - automatically displayed
F

. . . . . . . . . .Freeze Cycle

F flashes Freeze Cycle is Pending

H . . . . . . . . . .Harvest Cycle

H flashes . . . .Manual Harvest

b . . . . . . . . . . .Bin is Full
C . . . . . . . . . .Clean Cycle
L . . . . . . . . . . .Board Locked
d

. . . . . . . . . .Test Mode

O . . . . . . . . . .Off
E . . . . . . . . . . .Self Test Failed

1 flashes Max Freeze - Retrying

1 . . . . . . . . . . .Max Freeze Time Shut Down

2 flashes Max Harvest - Retrying

2 . . . . . . . . . . .Max Harvest Time Shut Down
3 . . . . . . . . . . .Slow Water Fill
4 . . . . . . . . . . .High Discharge Temp
5 . . . . . . . . . . .Sump Temp Sensor Failure
7 . . . . . . . . . . .Discharge Temp Sensor Failure

8 flashes Short Freeze - Retrying

8 . . . . . . . . . . .Short Freeze - Thin ice
Setting Codes - requires push button sequence
Water Purge Settings
A, 1, 2, 3, 4, 5
De-Scale notification
- see box to the right

Change De-Scale Notification Interval - This
feature is accessible only from standby
(Status Light Off).
1. Press and hold harvest button for 3 seconds.
This starts the Time to Clean Adjustment
Mode and displays the current time to clean setting.
2. Press the clean button repeatedly to cycle

through the 4 settings:

1 year

0 or disabled

4 months

6 months (default)

3. Push Off to confirm the selection.