beautypg.com

Scotsman Prodigy Series User Manual

Page 94

background image

January 2015 Page 94

Repair Section

Ice thickness sensor
1. Push and release the Off switch.
2. Remove front and top panels.
3. Push and release the Harvest switch
4. Remove the evaporator cover.
5. Remove the sound shield (when used).
6. Disconnect electrical power.

7. Open the control box.
8. Remove curtain.
9. Locate sensor, squeeze mounting legs together to release it from the mounting bracket.
10. Remove sensor, follow wire back to control box.
11. Disconnect from controller connection J10.
12. Remove sensor from machine.
13. Reverse to reassemble.
14. Set initial probe-to-evaporator-surface gap using a 7/32” drill bit as a gauge.

Electrical Shock Hazard
Disconnect electrical

power before beginning