beautypg.com

Test procedures – Scotsman Prodigy Series User Manual

Page 57

background image

January 2015 Page 57

Test Procedures -

Fan motor

1. Test using the controller’s indicator lights.
Note: Fan pressure control connection must be jumped to perform this test.
Put the controller into test mode (depress Off for 3 seconds then depress Clean for 3 seconds). At the end of

the test cycle, the fan motor will be powered and the Condenser Fan motor indicator light will be on. The fan

motor should start and run at that time. If it does not, repeat the test but check the voltage to the fan motor,

it must receive full voltage at the fan motor lead connection at the end of the test. If there is voltage and the

motor does not operate, replace the motor. If there is no voltage, check the controller high voltage harness

connection.
The fan motor lead is the top wire. Check voltage from it to ground, at the end of the test, when the fan motor

indicator light is On, there must be voltage from this pin to ground.
Note: high voltage power is supplied to the bottom pin from the contactor line. Refer to the machine

wiring diagram as needed.
2. Test using an ohmmeter. Disconnect electrical power. Unplug fan motor from harness. Measure fan motor

winding resistance. If open, replace the fan motor.

Fan Pressure Control, must CLOSE to

operate fan motor.

This light is ON when the fan motor

should be operating.

8 - Fan Motor

7 - Inlet Water Sol

6 - Water Pump

5 - Hot Gas Valve

4 - Compressor

3 - Purge Valve

1 - Line In

Brown

Blue

Yellow

Red

Black

Red

White

Brown

White