beautypg.com

Scotsman Prodigy Series User Manual

Page 60

background image

January 2015 Page 60

Test Procedure - Compressor contactor

1. Test using the controller’s indicator lights. When the unit is in ice making mode (continuous F in the display)

the compressor contactor will have power.
• Check the Compressor indicator light, when it is on the compressor contactor will have pulled in. If it is not,

do a voltage check.

• Place voltmeter leads on the coil of the contactor. There should be full voltage.
• If there is full voltage present and the contactor has not pulled in, replace the contactor.
• If there is no voltage check if the high pressure cut out is open. If the high pressure cut out is closed, check

for voltage from the controller to ground. The contactor pin is 4. Check from 4 to ground, or on 220 volt

models, to the other power leg (usually L2) when the compressor indicator light is on. There should be

voltage. If not, replace the controller.

• If there is voltage at the controller but not at the contactor coil, the harness wires or connectors are

damaged and must be replaced.

2. Test using an ohmmeter. Test the coil of the contactor for continuity or shorts to ground. Replace if open or

shorted.
3. Check connections and contacts. Be sure connections are tight and that the contacts are not burnt. Replace

any contactor with burnt contacts.

This light is ON when the compressor is

operating.

8 - Fan Motor

7 - Inlet Water Sol

6 - Water Pump

5 - Hot Gas Valve

4 - Compressor

3 - Purge Valve

1 - Line In

Brown

Blue

Yellow

Red

Black

Red

White

Brown

White