beautypg.com

Scotsman Prodigy Series User Manual

Page 9

background image

January 2015 Page 9

General Installation - Remote

Location Limitations
This ice system is made up of three parts, the ice making machine, or head; the remote condenser; and the

interconnecting tubing. The ice making machine must be installed indoors, in a controlled environment. Space

must be provided near the machine for service access. The remote condenser may be installed above or below

the ice machine, per the limits stated later in this manual. The remote condenser may be installed outdoors

within the temperature limits listed below. The interconnecting tubing must be installed per the directions stated

in this manual, and the amount of tubing exposed to uncontrolled temperatures must be minimized.

Space Limitations
Although the machine will function with no clearance to the top and sides, some space must be allowed for

service access. Building the machine in with no access will cause higher service cost, in many cases this extra

cost may not be covered by warranty.
Environmental Limitations, ice machine:
Minimum

Maximum

Air temperature

50

o

F.

100

o

F.

Water temperature 40

o

F.

100

o

F.

Water Pressure

20 psi

80 psi

Environmental Limitations, remote condenser
Minimum

Maximum

Air temperature

-20

o

F.

120

o

F.

Power Supply
Minimum

Maximum

115 volt model

104 volts

126 volts

208-230 volt model 198 volts

253 volts

Central Condenser Coils
The ice machine may be connected to a central condenser coil. The requirements are:
• Coil – not previously used with mineral oil system. Virgin coil preferred.
• Correct size (internal volume) and capacity (BTUH).
• Includes a headmaster valve for discharge pressure control. Headmaster kit available for certain MAC

condensers, kit number is RCKCME6GX.
• Fan motor on all the time or controlled to be on whenever the ice machine is operating.
• Non-Scotsman condensers must have prior Scotsman Engineering approval for warranty coverage to be in

effect.
Precharged tubing kits:
The ice making head’s and the remote condenser’s refrigeration circuits must be connected. They are

designed to be connected using precharged refrigerant tubing, supplied in kits of liquid and discharge tubes.

Several lengths are available, order the one that just exceeds the length needed for the site.
10” 25’

40’

75’

RTE10 RTE25 RTE40 RTE75
No additional refrigerant is required. Note: Refrigerant charge is supplied with the ice machine