Scotsman Prodigy Series User Manual
Page 8

January 2015 Page 8
Water purge setting
The water purge is factory set to the Automatic setting. The setting can be changed to one of 5 manual settings
or placed on automatic. The purge setting shows in the Code Display.
purge setting 1 - Minimum
2 - Moderate 3 - Standard 4 - Heavy
5 - Maximum A - Automatic
Water Type
RO water or
equivalent,
TDS less than
35
Low TDS non
- RO water
Setting for
typical water
High TDS
water
Very high
TDS water,
greater than
256
Any with
conductivity not
less than 10
microSiemens/
cm
To set:
Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display.
Press and release the On button repeatedly until the number on the display corresponds to the desired setting.
Press and release the Off switch again to return to the normal control state.
Product Description and Electrical Requirements
- See spec sheet or User's Manual for Minimum Circuit Ampacity or Maximum Fuse SIze
Dimensions w” x d” x h”
Model
Electrical
Use condenser
22 x 24 x 23
C0522SR-1
115/60/1
ERC111-1
same
same
same
ERC211-1**
30 x 24 x 23
C0530SR-1
115/60/1
ERC111-1
same
same
same
ERC211-1**
same
C0630SR-32
208-230/60/1
ERC311-32
30 x 24 x 29
C0830SR-32
208-230/60/1
ERC311-32
same
C0830SR-3
208-230/60/3
ERC311-32
same
C1030SR-32
208-230/60/1
ERC311-32
same
C1030SR-3
208-230/60/3
ERC311-32
48 x 24 x 29
C1448SR-32
208-230/60/1
ERC311-32
same
C1448SR-3
208-230/60/3
ERC311-32
same
C1848SR-32
208-230/60/1
ERC611-32
same
C1848SR-3
208-230/60/3
ERC611-32
same
C2148SR-32
208-230/60/1
ERC611-32
same
C2148SR-3
208-230/60/3
ERC611-32
** ERC211 has two circuits, when two C0522s or C0530s are connected to it, fan motor relay kit KCMR120
must be used to control the fan motor.
Not all models remain available. C0522 remote and ERC211 are discontinued.
Ratings include the remote condenser motor, as it is designed to be powered by the ice machine. If connecting
remote condenser independently of the ice machine, use the information on the condenser's dataplate for fuse
and wire sizes.
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code
omitted. All the listed condensers include a headmaster valve.