Diagnostics – Water Cooled

No ice

Problem

Likely Cause

Probable Solution

No power to unit

Power disconnected Check breaker or fuse.

Reset or replace, restart and check

No power to controller

Transformer open

Replace transformer

Shut down on maximum

water fill time

Water shut off

Restore water supply

Shut down on maximum

freeze time

Water leak

Check purge valve, curtain, sump, pump

hose

Ice thickness sensor dirty or disconnected

Check ice thickness sensor probe

Water distributor dirty

Remove and clean water distributor

Inlet water valve leaks through during freeze

Check inlet water valve

Connected to hot water

Check for bleed thru from / missing check

valve in building water supply

Incomplete harvest

Check harvest system

High pressure cut out opened

Water supply cut off, restore water supply

to condenser

Fan motor pressure control open

Check fan pressure control

Fan motor not turning

Check fan motor, check fan blade, check

controller using test mode

Water pump not pumping

Check pump motor, check controller

using test mode

Pump hose disconnected

Check hose

Compressor not operating

Check compressor contactor, check

controller using test mode
Check compressor start

components, check PTCR

resistance and temperature
Check compressor voltage
Check compressor windings

Low refrigerant charge

Add some refrigerant and restart unit. If

cycle time improves, look for leak.

Hot gas valve leaks through during freeze

Check hot gas valve for hot

outlet during freeze

Thermostatic expansion valve bulb loose

Check bulb

Thermostatic expansion valve producing very

low or very high superheat

Check evaporator superheat, change

TXV if incorrect

Compressor inefficient

Check compressor amp draw, if low and

all else is correct, change compressor